Grundo: Difference between revisions
(→Specs: Add other name for the Ethernet card) |
(→Speculation / History: Add Brad's response) |
||
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{Lowercase title}} |
{{Lowercase title}} |
||
The '''Motorola Net6200/166''' |
The '''Motorola Net6200/166''' is a machine I had been trying to find for about four years, then get running for about half a year. |
||
== Specs == |
== Specs == |
||
Line 31: | Line 31: | ||
* If you reboot the computer from within Windows NT, when the system reboots into the firmware, it will claim to not detect a keyboard (using COM1 instead) and then hang. The Num Lock key on the keyboard stays on. |
* If you reboot the computer from within Windows NT, when the system reboots into the firmware, it will claim to not detect a keyboard (using COM1 instead) and then hang. The Num Lock key on the keyboard stays on. |
||
* I have not yet been able to successfully boot from the optical drive. My retail Windows NT 4.0 Workstation CD bombs out immediately in Windows Setup about not being able to load the CD-ROM device, and the device it tries to load does not change with the value of <code>OSLOADPARTITION</code>. Other CDs, like for old versions of PowerPC Linux distros, don't get past the Forth interpreter regardless of how I try to <code>boot</code> the files on them. |
* I have not yet been able to successfully boot from the optical drive. My retail Windows NT 4.0 Workstation CD bombs out immediately in Windows Setup about not being able to load the CD-ROM device, and the device it tries to load does not change with the value of <code>OSLOADPARTITION</code>. Other CDs, like for old versions of PowerPC Linux distros, don't get past the Forth interpreter regardless of how I try to <code>boot</code> the files on them. |
||
* The back of the case calls the serial port "COMM 1" (2x M), while the firmware calls it "com1" (1x M). |
|||
== Reconstructing the boot configuration == |
== Reconstructing the boot configuration == |
||
Line 53: | Line 54: | ||
** primary DNS server of <code>134.48.1.32</code> |
** primary DNS server of <code>134.48.1.32</code> |
||
** secondary DNS server of <code>134.48.1.31</code> |
** secondary DNS server of <code>134.48.1.31</code> |
||
* Apparently Microsoft discontinued Windows NT for PowerPC a mere month after PowerStack II machines entered production.<ref>https://archive.org/details/MacWorld9703March1997/page/n37/mode/1up?q=Powerstack</ref> |
|||
* In response to there being an existing commercial third-party PowerPC Windows NT application on disk, Revexia says: <blockquote>For the PowerPC port of NT? Wtf, I mean like I knew that was possible but I struggle to imagine why anyone would actually want to use a PPC for NT. I can think of a million purpose built NT machines that would just have been easier to use. Wonder if that university just had a bunch of expensive PPCs leftover and a mandate to transition to Windows for integration with other systems. Let us know what you figure out!</blockquote> |
* In response to there being an existing commercial third-party PowerPC Windows NT application on disk, Revexia says: <blockquote>For the PowerPC port of NT? Wtf, I mean like I knew that was possible but I struggle to imagine why anyone would actually want to use a PPC for NT. I can think of a million purpose built NT machines that would just have been easier to use. Wonder if that university just had a bunch of expensive PPCs leftover and a mandate to transition to Windows for integration with other systems. Let us know what you figure out!</blockquote> |
||
=== Dr. Dennis Brylow's email === |
|||
<blockquote> |
|||
Dear Hunter, |
|||
This is fascinating. The machine you speak of would likely predate me; |
|||
When I got to Marquette in 2005, there were no such unusual machines in |
|||
service in the then Math/Stats/Computer Science Department. To my |
|||
knowledge, I was the only one on campus running Yellow Dog Linux on |
|||
PowerPC-based machines in the 2005-2010 time range. Engineering is |
|||
a separate college, and has their own system administration team, so they |
|||
might know more. But we'd definitely need to seek out folks who were |
|||
involved in lab infrastructure at the time. |
|||
I can suggest two leads, if you haven't contacted them already. Mr. |
|||
Steve Goodman <steven.goodman@marquette.edu>, our computer science |
|||
department director of technology, did a prior stint here at Marquette the |
|||
decade before my arrival, and may have had contact with this Net6200 |
|||
machinery. I know we had a ton of PowerPC-based "Java Stations" in some of |
|||
the computer labs in Cudahy Hall back in the day; they were all relegated to |
|||
storage in the back room by the time I got here, but it sounds similar to |
|||
what you're asking about. There were dozens of them. |
|||
I had briefly investigated them as backend machines for our RISC-based |
|||
embedded operating systems infrastructure, but there was very little |
|||
documentation available anywhere on them, and the work wasn't going to be |
|||
replicable at other schools if they couldn't get their hands on those |
|||
things. It would be somewhat unusual for Engineering to have such equipment |
|||
lurking in their labs if they weren't already being used at scale elsewhere |
|||
on campus. Your theory that Eng142 probably had a prior life rings true. I |
|||
can't imagine Engineering investing in a PowerPC-based WinNT workstation, |
|||
but it definitely could have been a repurposing of a relatively expensive |
|||
piece of hardware after one of the special-purpose computer labs had moved |
|||
on to new workstations. If so, its original home would probably have been |
|||
in the MSCS Department in Cudahy Hall, or perhaps even earlier before the |
|||
move over from the Physics building in the 1990's. |
|||
My second lead would be to reach out to Brad Bonczkiewicz |
|||
<brad.bonczkiewicz@marquette.edu>, director of technology over in the |
|||
College of Engineering. He's been around here a long time, and might know |
|||
something about how this machine came to be in the eng.mu.edu domain. |
|||
Let me know if you'd like me to make electronic introductions to either |
|||
or both of these two gentlemen. I'm certainly curious to hear what you |
|||
learn. |
|||
Best Regards, |
|||
Dennis |
|||
</blockquote> |
|||
=== Brad Bonczkiewicz's email === |
|||
<blockquote> |
|||
Hi Hunter, sorry I do not have any additional information about the computer. Our records go back around 20 years which wouldn't include this system. While I've been in my position 15+ years, I have made every effort to ensure the hard drives are wiped before being disposed. If this was university property, it is critical we delete all user data, configuration files/accounts/passwords, and Marquette-licensed software for both legal and liability purposes. I would greatly appreciate if you would not connect the computer to the Internet and erase the drive when you are completed. While I do remember Windows NT 4 as a student in college, I don't remember the Motorola hardware and its unusual to find a PowerPC that is not inside of a Mac. Very interesting find and project to restore. Good luck |
|||
</blockquote> |
|||
== Things to archive == |
== Things to archive == |
||
Line 136: | Line 192: | ||
* 2024-01-14: {{Upgrade|21 capacitors are replaced (8 on processor card, 13 on motherboard.}} |
* 2024-01-14: {{Upgrade|21 capacitors are replaced (8 on processor card, 13 on motherboard.}} |
||
* 2024-01-24: {{Upgrade|The correct RAM is installed.}} |
* 2024-01-24: {{Upgrade|The correct RAM is installed.}} |
||
* 2024-02-04: The original Administrator password is recovered. |
|||
== References == |
|||
<references /> |
|||
[[Category:Computers]] |
[[Category:Computers]] |
Latest revision as of 15:07, 12 July 2024
The Motorola Net6200/166 is a machine I had been trying to find for about four years, then get running for about half a year.
Specs
system-id
00 ff ff 58 08 00
name
- FirePower,Powerized_LX MP
- Processor
- 2x PowerPC 604e @ 166 MHz
- Memory
- 8 72-pin SIMM module slots
- Hard disk
- Seagate BarraCuda 4 Series 4.29 GB 7200RPM Fast Wide SCSI 1MB Cache
- Display adapter
- Cirrus Logic GD5446 Rev A
- VRAM
- 2 MiB
- Ethernet adapter
- ZNYX NetBlaster ZX345 (SA0025) -- Windows NT detects this as a DEC PCI Fast Ethernet DECchip 21140
- SCSI card
- Adaptec AHA-2940UW
- Expansion
- 4 Conventional PCI slots, 3 16-bit ISA slots
- Clock battery
- Duracell 3V DL1/3N (one-third N)
- Serial number
- MP00176
- Motherboard label
- MLU, LX SERIES 01-07582-03 (FIREPOWER SYSTEMS INC), serial LXM01113
- Firmware version
- Version 03.03
- Firmware timestamp
- 1996-09-19,01:47:29
- Capacitors
- 21 of 25NXA220MEFC10X12.5 CAP ALUM 220UF 20% 25V RADIAL
Quirks
- The motherboard is labeled Firepower Systems, Inc. instead of Motorola.
- When the system was first powered on, it booted enough to give a "no RAM" beep. Later attempts did not give a beep. There are four diagnostic LEDs on the board labeled A, B, C, D. When booting with RAM, light A stays on. When booting with no RAM, light C stays on. When booting with no processor card, no lights stay on. The beep no longer happens. Purple believes this may be due to the capacitors no longer being able to function properly and only managed to work for the initial power-on before becoming useless for further attempts.
- After recapping, we discovered that when COMM 1 is attached to serial at 19200 baud, the system prints "AbcdefgBCD", first the first seven characters, then a pause, then the last three. Sometimes, it gets to "AbcdefgBCDE" after a second pause. Sometimes, there is a garbage character instead of this 'E'. Our hypothesis after this was that the machine doesn't like non-ECC RAM.
- After installing two sticks of EDO ECC 60ns RAM, the machine finally boots.
- The machine cannot be run without a keyboard. It will read garbage off the keyboard port and endlessly try to interpret invalid Forth commands, as seen from the serial console.
- Serial output only goes past "install-console" if no display is connected.
- Apparently the hard disk is using a beta firmware.
dev /pci/scsi@3 .properties
outputsv1.00 Beta 7
forversion
. - The registry files found on disk do not work with any of the available offline Windows NT password manipulation tools available. I had to manually find the encrypted LM hash in the registry, decrypt it, and then brute-force the original password for the Administrator account (which is: computer). See: Old-style Windows NT LM hash recovery
- If you reboot the computer from within Windows NT, when the system reboots into the firmware, it will claim to not detect a keyboard (using COM1 instead) and then hang. The Num Lock key on the keyboard stays on.
- I have not yet been able to successfully boot from the optical drive. My retail Windows NT 4.0 Workstation CD bombs out immediately in Windows Setup about not being able to load the CD-ROM device, and the device it tries to load does not change with the value of
OSLOADPARTITION
. Other CDs, like for old versions of PowerPC Linux distros, don't get past the Forth interpreter regardless of how I try toboot
the files on them. - The back of the case calls the serial port "COMM 1" (2x M), while the firmware calls it "com1" (1x M).
Reconstructing the boot configuration
The hard disk is configured like this:
- Partition 1: 10 MB FAT16 partition. This contains firmware-readable executables.
- Partition 2: Points to an extended partition (partition 5).
- Partition 5: NTFS partition.
Given this configuration, I was able to boot off the hard disk with the following commands:
setenv OSLOADPARTITION multi(0)scsi(0)disk(0)rdisk(0)partition(2) boot disk:,\OS\VENEER.EXE \OS\WINNT40\OSLOADER.EXE
Speculation / History
- The computer originally came from Marquette University. There is an FTP log on the hard disk with many entries for vmsb.csd.mu.edu. Additionally, the registration information in the System Properties dialog says Engineering, Marquette University. It originally had a:
- hostname of
eng142
- domain of
eng.mu.edu
- static IP address of
134.48.93.142
- subnet mask of
255.255.255.0
- default gateway of
134.48.93.100
- primary DNS server of
134.48.1.32
- secondary DNS server of
134.48.1.31
- hostname of
- Apparently Microsoft discontinued Windows NT for PowerPC a mere month after PowerStack II machines entered production.[1]
- In response to there being an existing commercial third-party PowerPC Windows NT application on disk, Revexia says:
For the PowerPC port of NT? Wtf, I mean like I knew that was possible but I struggle to imagine why anyone would actually want to use a PPC for NT. I can think of a million purpose built NT machines that would just have been easier to use. Wonder if that university just had a bunch of expensive PPCs leftover and a mandate to transition to Windows for integration with other systems. Let us know what you figure out!
Dr. Dennis Brylow's email
Dear Hunter,
This is fascinating. The machine you speak of would likely predate me; When I got to Marquette in 2005, there were no such unusual machines in service in the then Math/Stats/Computer Science Department. To my knowledge, I was the only one on campus running Yellow Dog Linux on PowerPC-based machines in the 2005-2010 time range. Engineering is a separate college, and has their own system administration team, so they might know more. But we'd definitely need to seek out folks who were involved in lab infrastructure at the time.
I can suggest two leads, if you haven't contacted them already. Mr. Steve Goodman <steven.goodman@marquette.edu>, our computer science department director of technology, did a prior stint here at Marquette the decade before my arrival, and may have had contact with this Net6200 machinery. I know we had a ton of PowerPC-based "Java Stations" in some of the computer labs in Cudahy Hall back in the day; they were all relegated to storage in the back room by the time I got here, but it sounds similar to what you're asking about. There were dozens of them.
I had briefly investigated them as backend machines for our RISC-based embedded operating systems infrastructure, but there was very little documentation available anywhere on them, and the work wasn't going to be replicable at other schools if they couldn't get their hands on those things. It would be somewhat unusual for Engineering to have such equipment lurking in their labs if they weren't already being used at scale elsewhere on campus. Your theory that Eng142 probably had a prior life rings true. I can't imagine Engineering investing in a PowerPC-based WinNT workstation, but it definitely could have been a repurposing of a relatively expensive piece of hardware after one of the special-purpose computer labs had moved on to new workstations. If so, its original home would probably have been in the MSCS Department in Cudahy Hall, or perhaps even earlier before the move over from the Physics building in the 1990's.
My second lead would be to reach out to Brad Bonczkiewicz <brad.bonczkiewicz@marquette.edu>, director of technology over in the College of Engineering. He's been around here a long time, and might know something about how this machine came to be in the eng.mu.edu domain.
Let me know if you'd like me to make electronic introductions to either or both of these two gentlemen. I'm certainly curious to hear what you learn.
Best Regards, Dennis
Brad Bonczkiewicz's email
Hi Hunter, sorry I do not have any additional information about the computer. Our records go back around 20 years which wouldn't include this system. While I've been in my position 15+ years, I have made every effort to ensure the hard drives are wiped before being disposed. If this was university property, it is critical we delete all user data, configuration files/accounts/passwords, and Marquette-licensed software for both legal and liability purposes. I would greatly appreciate if you would not connect the computer to the Internet and erase the drive when you are completed. While I do remember Windows NT 4 as a student in college, I don't remember the Motorola hardware and its unusual to find a PowerPC that is not inside of a Mac. Very interesting find and project to restore. Good luck
Things to archive
The disk image is "motorola.img" on the NAS.
- There is a surviving third-party commercial PowerPC Windows NT application! It is a version of something called ExecSoft Diskeeper.
- Installer for Microsoft Internet Explorer 3.01 for PowerPC
- Various hotfixes specifically for PowerPC (checked with
file
on Linux) - The copies of Veneer, OSLoader, HAL, and the drivers directory (requested by Rairii at: https://haqueers.com/@Rairii/111851384631484546)
Documentation
- Q132858: PowerStack with Cirrus Video Adapter Hangs During Startup (variants)
- Q140475: PRB: Unable to Print to LPT1: Under Windows NT on Motorola (variants)
- Q153399: Add-in Display Adapters and Motorola Powerstack Computers (variants)
- Q154720: Using FDOS on the PowerPC (variants)
- Q154831: Arcinst Not Available for PPC (variants)
- Q154855: System Reserved Partitions on PowerPCs (variants)
- Q155407: Setting Up Windows NT on Motorola PowerStack When Drive Is New (variants)
Potential documentation
- https://web.archive.org/web/19970605064417/http://www.mot.com/GSS/MCG/support/hard/index.html
- https://www.vogons.org/viewtopic.php?t=71225
What a successful boot looks like over the serial port
AbcdefgBCDElxhHjklmBCDEoFGIJKLMN$1234#noFGIJKLMN$1234#stand-init /pci/isa/interrupt-controller init init-slaves master-cache-on /pci/isa/rtc /pci/isa/nvram init-nvram-buffer init-options init-security / clock frequency more-memory ?bailout scrub-memory hardware-kludge copy-reboot-info nvramrc probe-all probe-isa probe-pci get-mac-address probe-onboard probe-ide init-scsi init-ide install-console
History
- 2023-09-09: The computer is purchased at VCF Midwest. The seller states that the computer had been stored in a barn near Racine.
- 2023-09-10: The computer is temporarily transported to my parents' place.
- 2023-09-28: The computer is transported to the new home.
- 2023-12-16: 📈 The clock battery is replaced. Before replacing, it was measuring 2.9 V.
- 2023-12-16: The capacitors on multiple components are identified as bad.
- 2024-01-14: 📈 21 capacitors are replaced (8 on processor card, 13 on motherboard.
- 2024-01-24: 📈 The correct RAM is installed.
- 2024-02-04: The original Administrator password is recovered.